Data Center Raised Access Floor for Cooling System

A data-centre raised floor integrating load, airflow, cabling, grounding and maintenance.

Recommended Thickness35 mm
Maximum Panel Size600 × 600 mm
  • Complete Raised Floor System

  • Multi-Utility Void

  • Equipment Maintenance Access

WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
img of mask_layer_close
Data Center Raised Access Floor for Cooling System
Data Center Raised Access Floor for Cooling System
Data Center Raised Access Floor for Cooling System
Data Center Raised Access Floor for Cooling System
Data Center Raised Access Floor for Cooling System
  • Product Detail
  • Specifications
  • Applications
  • FAQ

01 / Product Positioning

Data Center Raised Access Floor for Cooling System

Solid and perforated panels, pedestals, stringers, grounding and perimeter sealing create a controlled void for cooling air, power and data cabling and equipment maintenance.


Data Center Raised Access Floor for Cooling System with solid and perforated panels, pedestals, stringers, grounding and perimeter sealing creating a controlled void

02 / Application-specific value

Advantages for Cooling System

02
01

Complete Raised Floor System

Solid and perforated panels, pedestals, stringers, grounding, and perimeter sealing create a unified structural system for data center environments.

02

Multi-Utility Void Solution

Forms a controlled void for cooling air, power and data cabling routing with equipment maintenance access.

03

Optimized Cooling Strategy

Supports cold-aisle strategy and heat load management for efficient thermal performance.

04

Comprehensive Selection Criteria

Includes configurable building use, finished floor level, void height, cable capacity, concentrated and uniform loads, partition locations, finish system, maintenance frequency, and installation programme.

Solid, perforated and access panels zoned with pedestals, stringers and grounding details to maintain stability and electrical continuity in a data center raised floor

03 / Composition and surface options

Inorganic core, reinforcing layers and finishing surfaces

The system zones solid, perforated and access panels and uses pedestals, stringers and grounding details to maintain stability and electrical continuity.



04 / Key features

Performance defined for the confirmed model

04
FeatureFinal Product Information
System positioningSolid and perforated panels, pedestals, stringers, grounding and perimeter sealing form a common platform for airflow, cabling, load support and maintenance in data centres.
Functional zoningSolid, perforated and access panels must be zoned around racks, cold aisles, cable trays and maintenance routes.
System load performancePanel grade, pedestal and stringer arrangement, equipment feet and transport routes must be checked as one load-support system.
Product boundaryPanel data alone cannot prove airflow efficiency, grounding continuity or room-wide anti-static performance.
Model-specific dataPerformance follows the technical data and reports for the confirmed model.
System-level boundaryPanel data does not replace complete-wall validation.
Document alignmentSample name, thickness, density and surface should match the supplied model.

Inquire Now
Name: *
Mobile:
E-mail: *
Message: *
Verification code: *
  
Other products
ADDRESS

No. 38, Guanhe East Road, Tianning District, Changzhou City, Jiangsu Province

Tel.

0086-13382801598

Follow Us

Follow us on our Social Media

CopyRight © 2026 - Jiangsu Massif Building Materials Co., Ltd.  All rights reserved  Sitemap All tags  Designed by Zhonghuan Internet